Active Standard

IEEE/ANSI C63.18-2014

American National Standard Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Electromagnetic Immunity of Medical Devices to Radiated Radio-Frequency (RF) Emissions from RF Transmitters

A guide to evaluating electromagnetic immunity of medical devices against radiated radio-frequency (RF) emissions from common RF transmitters is provided in this recommended practice (e.g., two-way radios; walkie-talkies; mobile phones; wireless-enabled tablets, e-readers, laptop computers, and similar devices; RFID readers; networked mp3 players; two-way pagers; and wireless personal digital assistants [PDAs]). A comprehensive test or a guarantee is not provided by this protocol but, instead, a basic evaluation is given that can help identify medical devices that might be particularly vulnerable to interference from common RF transmitters. Existing or newly purchased medical devices can be evaluated by this ad hoc test protocol or the protocol can be implemented for prepurchase evaluation. This recommended practice applies to medical devices used in health-care facilities but can also be adapted to medical devices in home health-care or mobile health-care settings. It does not apply to implantable medical devices (e.g., pacemakers and defibrillators), transport environments such as ambulances and helicopters, or RF transmitters rated at more than 8 W of output power. Testing with transmitters greater than 8 W in health-care facilities is not recommended because of possible adverse effects on critical care medical devices that are in use in nearby areas of the facility. Finally, in-band RF interference where the fundamental frequency of an RF transmitter overlaps with frequencies used by a hospital wireless network or monitoring or other medical device wireless links is not addressed by this recommended practice.

Standard Committee
USEMCSC C63 -
Status
Active Standard
Superseding
C63.18-1997
History
ANSI Approved:
2014-05-16
Published:
2014-06-20

Working Group Details

Society
Society
Committee on Electromagnetic Compatibility
Standard Committee
USEMCSC C63 -

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter