Inactive-Reserved Standard

IEEE 1861-2014

IEEE Guide for On-Site Acceptance Tests of Electrical Equipment and System Commissioning of 1000 kV AC and Above

On-site acceptance tests of ultra-high-voltage power equipment are subject to this guide. Criteria and requirements for test items, conditions, methods, and results are established. The stated specifications and requirements, both technical and for testing, are universally needed for acceptance tests on-site and commissioning of ultra-high-voltage power equipment, including power transformers, reactors, capacitive voltage transformers, bushing-type current transformers, gas-insulated switchgear, air insulated grounding switches, air insulated disconnecting switches, bushings, metal-oxide surge arresters, suspension insulators, post insulators, and insulating oil, etc. It will be sufficient for most installations.

Standard Committee
PE/SWG - Switchgear
Joint Sponsors
PE/TR
PE/SWG
PE/SUB
Status
Inactive-Reserved Standard
PAR Approval
2012-06-08
Board Approval
2014-06-12
History
Published:
2014-08-01
Inactivated Date:
2025-03-27

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/SWG - Switchgear
Working Group
UHV-WG - DELETE - Ultra-High Voltage Working Group - DELETE
IEEE Program Manager
Soo Kim
Contact Soo Kim
Working Group Chair
Weijiang Chen

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P1861
Recommended Practice for On-Site Acceptance Tests of Electrical Equipment and System Commissioning of 1 MV Alternating Current (ac) and Above

This Recommended Practice applies to on-site acceptance tests and system commissioning of Ultra-High Voltage (UHV) 1 MV ac and above power equipment. It provides criteria and recommendations for UHV test equipment, conditions, methods, and results. UHV power equipment includes: • Power transformers • Reactors • Gas-insulated transmission lines (GIL) • Capacitive voltage transformers (CVTs) • Gas-insulated switchgear • Air insulated grounding switches • Air insulated disconnecting switches • Bushings • Metal-oxide surge arrestors (MOSAs) • Suspension insulators • Post insulators • Associated insulating oil.

Learn More About P1861

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.